Thông tin liên hệ

Địa chỉ: 307 Phạm Văn Bạch, Phường 15, Q.Tân Bình, TP.HCM

Liên hệ: (028) 6287 4765 - (028) 6287 4769 - 0913 765 645 - 0984 677 378

Email : sales@thietbihiepphat.com

Microbiological Incubator with 2 compartments JSR JSGI-250DT

Contact Us

Tổng quan

JSR 2-compartment microbiological incubator model JSGI-250DT suitable for incubation needs of bacteria, fungi, cells cells and tissues on a temperature scale of +5°C to 70°C.

Some outstanding parameters of the series Microbiological incubator 2 compartments strong> JSR model JSGI-250DT:

 + Temperature scale: Ambient temperature +5 to 70°C

 + Volume: 500 Liters

 + Temperature accuracy: ±0.3°C

 + Temperature uniformity: ±1.5°C

Features of Microbiological incubator 2 compartments JSR model JSGI-250T:

Performance

– Temperature control in the range of Ambient Temperature +5 to 70°C.

– The air inside is forced by fan convection for high temperature uniformity and accuracy.

– The cabinet is designed with a circulating fan for superior temperature uniformity.

– Heating resistors are installed independently on the back of the cabinet to prevent contamination and easy to maintain.

Controllers

– Temperature control by microprocessor PID controller.

– User-friendly, backlit LCD display.

– UV coated Polycarbonate touch panel.

– There is a knob to change the setting value easily.

– Display resolution 0.1°C.

– Set time up to 99 hours 59 minutes and with warnings.

– Function to remember commonly used temperature and time values.

– Calibration settings at 3 points, 1 point offset.

– Function to restore setting data after power failure.

– Pt100Ω Class A probe.

– RS-232 computer connection port (option).

Structure

– The cabinet is made of durable eopxy coated metal.

– The cabinet is made of anti-corrosion 304 stainless steel, the inner corners are rounded for easy cleaning and leak prevention.

– Inner tempered glass door for easy viewing of samples.

– Port for connecting cables.

Convenient

– The exterior door has a self-closing magnet.

– Inner glass door with high density silicone gasket helps the door to be sealed airtight.

– The inner tray is removable and adjustable in height.

– The switch automatically disconnects the resistor and fan when the sampling door is opened.

Safety

– Door sensor with audible alarm when opening the door.

– Set maximum temperature limit, heating cut-off and audible warning.

– Stops heating when the temperature exceeds +2°C above the set temperature.

– Warning and power off when the temperature is too high.

– Warning and power off when the temperature is too low.

– Warning when connection to thermal probe is lost.

– Power cut off when voltage exceeds: fuse.

Send Require

Leave your questions, we will answer them right away

THÔNG TIN KHÁCH HÀNG

Cảm ơn quý khách đã liên hệ

chúng tôi sẽ liên hệ với quý khách trong thời gian sớm nhất