Kruss Model FP8600 Automated Sample Pump Top Photometer with Model FP8600 is a laboratory model with the addition of a sampler for up to 72 sample positions. Once installed, the FP8600 automatically measures up to 72 samples in a single run. Especially laboratories and measurement and testing centers are best suited for this solution.
Kruss Model FP8600 Kruss Automatic Sample Pump Top Photometer allows simultaneous measurement of Na, K, Ca and Li elements. 5 measurement channels are available for this, which can be configured separately. Thanks to proven measurement methods and modern electronics, the Kruss flame photometer achieves highly accurate and reproducible measurement results, and is a simple and affordable alternative. particularly cost-effective than comparable analytical techniques such as ICP or AAS.
Excellent Features:
– Reliable measurement, measuring up to 5 alkaline and alkaline earth elements
– Works automatically for large samples
– Dispenses sample without dilution
– Low maintenance by the user
– Very high precision
– Maximum operational safety through intelligently secured systems
– User administration with two levels of permissions
– Allows full retrieval of measurement results
– Extensive interface optimized for data transmission for simplicity and convenience
– Complies with international standards such as GMP/GLP and 21 CFR Part 11
Excellent performance:
Optimize workflow with automation feature
– Capable of measuring up to 300 samples/hour. – The device operates with almost no need for routine user maintenance |
|
Intuitive operation
Kruss flame photometer is easy and intuitive to operate with its large touchscreen display and can be connected to a control mouse via USB. ■ User administration with two levels of permissions ■ Retrieve the origin of all measurement data and device settings ■ Full retrieval of measurement results ■ Extended interface optimizes data transmission for simplicity and convenience ■ Complies with international standards such as GMP/GLP and 21 CFR Part 11 |
|
Premium safety feature
Auto shut off: ■ When the fire has been extinguished ■ With frequent system shutdown ■ In case of power failure ■ When fuel, oxidizer or coolant pressure is low ■ When fuel gas is low or air pressure or cooling air malfunction Safety functions are monitored by an independent safety system |
|
Calibration, sample measurement , controls and standards
■ Water samples, controls and standards are measured manually or automatically. Calibration is done through standards. Measurement results can be checked by the controller. ■ Actual value and concentration value of calibration are displayed graphically and in tabular form for checking. |