Hydrometer Manual Sample Measurement Kruss Set 2
Contact Us
Tổng quan
Sản phẩm & cấu hình
Bill Tweight Ke strong>Manual Sample Measurement Kruss Set 1 is the perfect solution for manual sample delivery via syringe, especially for with low sample volume and high viscosity sample.
While the template is added, you can check for air bubbles by looking through the inspection glass. A suitable medium is injected for cleaning until all sample residues have been dissolved and removed. The drying unit then removes all liquid residue.
Excellent Features:
– Supply and clean sample through syringe
– Easy and intuitive operation via touch screen
– The menu has built-in calibration functions for easy user implementation
– User-selectable preset scales such as density, relative density, brix, alcohol and sulfuric acid concentration
– Complies with global standards and regulations such as GMP/GLP, 21 CFR Part 11, Pharmaceutical (USP, BP, JP, Ph. Eur.), FDA, ISO , HACCP, OIML, ASTM, ICUMSA, NIST
Excellent performance:
Unlimited measurement methods
■ Any method and any way of parsing the template can be created by the user ■ Method parameters: Scale, temperature, sampler, cut-off value, comments and more ■ Measurement mode: Single, continuous or preset interval measurement ■ Predefined scales (density, relative density, Brix, concentration of alcohol and sulfuric acid) ■ Allows the option to convert measured values based on the reference table |
|
Complete recording and data backup material
■ Record all measured data and measurement system or method selections in secure, edit-proof data storage ■ Stores up to 999 numbered measurements from small to large, and does not allow deletion |
|
Intuitive operation
■ Modern touch screen ■ Consistent performance of all other KRUSS lab instruments ■ Display 2 measurements simultaneously with 2 units of measure ■ Quick-adjust icons for the most important functions on the home screen can be customized ■ Easy to use, easy to adjust to the menu displayed by the user guide ■ There are 6 freely selectable languages (de, en, es, fr, it, pt) |
|
Flexible data retrieval
■ Print data to an ASCII printer (dot matrix printer) ■ Print data in PDF or PS format ■ Print data in PDF format on a USB stick or via Network share ■ Export data in HTML or CSV format to a USB stick or to a network share ■ Can be connected to an external keyboard, mouse, barcode scanner or PC to use KrüssLab ■ Integrates easily into existing networks (DHCP-Client) or LIMS |
|
Multiple density solutions:
■ DS7700 with ±0.001 g/cm³ accuracy and ■ DS7800 with ±0.0001 g/cm³ accuracy ■ Set 1 with manual measurement (using syringe) |
|
Complies with global standards
■ GMP / GLP ■ 21 CFR Part 11 ■ Pharmacopoeia (USP, BP, JP, Ph. Eur.) ■ FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST |
|
Fast reliable measurement
■ Drying unit with silica gel helps in measuring accuracy ■ Efficient temperature control with Peltier technology ■ Allows measurements to be manually preset or optimized with auto stability detection ■ Measured values can be previewed and updated every second |
|
Simple measure and do clean easily
■ Provide sample via syringe, peristaltic pump, or autosampler ■ Includes compactors and flow protection into the stable U-tube ■ Check the filling ability of the U-tube and the glass top of the device, for reliable operation ■ Chemical resistant material ■ Cleaning procedure is configured according to user requirements ■ Semi-automatic or fully automatic drying function |
|
Informative user administration features Minh
■ Can be activated or deactivated as required ■ Allows creating different admin levels ■ User Profile Setup ■ Custom settings for different users or workgroups |
Sampling options
Order Number | DS7700-1 | Hydrometer for manual sample measurement by syringe |
Image | ||
Provide includes | ||
DS7700 | Hydrometer with ±0.001 g/cm³ accuracy | |
DS7050 | 2/2 valve dryer | |
DS7001 | Tygon tube set: Air hose, exhaust pipe, Luer connection | |
DS7005 | Luer connector | |
DS7009 | Luer syringe, 2ml, 10pcs | |
DS7010 | Luer syringe, 10ml, 10pcs | |
DS7019 | Waste container with PE lid, 600ml |
Order Number | DS7800-1 | Hydrometer for manual sample measurement by syringe |
Image | ||
Provide includes | ||
DS7800 | Hydrometer with ±0.0001 g/cm³ accuracy | |
DS7050 | 2/2 valve dryer | |
DS7001 | Tygon tube set: Air hose, exhaust pipe, Luer connection | |
DS7005 | Luer connector | |
DS7009 | Luer Syringe, 2ml, 10pcs | |
DS7010 | Luer syringe, 10ml, 10pcs | |
DS7019 | Waste container with PE lid, 600ml |
- Đơn vị đo:
- Thang đo:
- Độ chính xác:
- Density [g/cm³], Relative Density, Brix [%Brix], Concentration of alcohol [vol%], Concentration of sulphuric acid [wt%], User-defined
- 0–3 g/cm³
- ±0.001 g/cm³
- Density [g/cm³], Relative Density, Brix [%Brix], Concentration of alcohol [vol%], Concentration of sulphuric acid [wt%], User-defined
- 0–3 g/cm³
- ±0.001 g/cm³
- Density [g/cm³], Relative Density, Brix [%Brix], Concentration of alcohol [vol%], Concentration of sulphuric acid [wt%], User-defined
- 0–3 g/cm³
- ±0.001 g/cm³
Leave your questions, we will answer them right away